Wind Pressure Calculator

IS 875 Part 3 · NBC 2016

Rectangular clad buildings. Calculate governing inward pressure, outward suction and local suction at the full building height. Review the calculation basis and highlighted Table 8 assumptions. Supported height range: 10–500 m; multiple height zones are not included.
Report details Optional until report submission
These details will appear in the report and be saved in the private AYFAAY project register when you submit a report.

Building & location

Select a citySource: NBC 2016, Part 6, Section 1, Annex C (Clause 4.4.2). Basic wind speed at 10 m height.
Advanced optionsWind-speed factors, pressure factors and pressure coefficients

Wind-speed factors

General buildings and structures.
k4 source: NBC 2016, Part 6, Section 1, Clause 4.4.3.4. Custom values require a project-specific basis.k3: editable · permitted range 1.00–1.36. Default 1.00 assumes no significant topographic amplification; confirm site conditions. NBC 2016, Clause 4.4.3.3 / Annex E.k1: table value 1.00 for 50-year general buildings.k1 source: NBC 2016, Part 6, Section 1, Table 4 (Clause 4.4.3.1). k3 defaults to 1.0; confirm applicable project factors.
Terrain factor, k2Select terrain category
Uses full building height h. Linear interpolation between tabulated heights.
Source: NBC 2016, Part 6, Section 1, Table 5 (Clause 4.4.3.2.2).

Design wind pressure factors

1.00Kd = 1.00 for local pressure coefficients.
—
Table 7: A ≤ 10 m² → 1.00; 25 m² → 0.90; A ≥ 100 m² → 0.80. Linear interpolation between these areas.Default Kc = 1.00. Select 0.90 only for combined wind loads on clad-building frames when roof pressure and internal suction act together, or vice versa, per NBC 2016 Clause 4.5.3.3.13. Confirm applicability to the element being checked.Source: NBC 2016, Part 6, Section 1, Clauses 4.5.2, 4.5.2.1 and 4.5.2.2 / Table 7.

Pressure coefficients

Internal pressure coefficient, Cpi±0.50
Check both positive and negative internal pressure. Confirm the opening ratio for the project.
External pressure coefficient, Cpe—
Table plan: A left, B right, C top, D bottom; 0° wind approaches A, 90° approaches C.
Local Cpe · edge zone—
Local edge-zone coefficient is shown separately; it is not substituted for the selected wall coefficient.NBC 2016, Part 6, Section 1, Table 8 (Clause 4.5.3.3.1). Direct lookup uses h/w and l/w, wall surface A–D and wind direction. For h/w ≥ 6, nearest l/w case selection is a calculator assumption requiring confirmation.

Building geometry

hlwElevationPlan
Height / width · h/w1.50
Length / width · l/w2.00

Wind pressure results

Preliminary checks only. A PASS result is not design approval. Further analysis, member optimisation and independent verification by a qualified engineer are required before project use. Read the engineering disclaimer. For a professionally reviewed submission report, contact AYFAAY.
Basic wind speed, Vb— m/s
Terrain factor, k2—
Design wind speed, Vz— m/s
Wind pressure at height, pz— kPa
Design wind pressure, pd— kPa
Internal pressure coefficient, Cpi±0.50
Typical areas — positive wind pressure— kPa
Typical areas — negative wind pressure— kPa
Corner / Local — negative wind pressure— kPa
Click CALCULATE to check all four surfaces at 0° and 90°, with both internal-pressure signs.

Calculation report

Payments are not enabled yet. Reports are currently free.

Two A4 pages with inputs, calculation steps, pressure coefficients and results.

Preview sample reportPreview uses demonstration inputs only. It contains none of your project details or calculated results. Actual reports are currently free; payment will be added later.

Your PDF is saved locally through the print window. Email is recorded for project reference; automatic email delivery is not enabled.

Only the AYFAAY register owner can view stored records. Contact info@ayfaay.com for a correction or deletion request. No visitor sign-in is required.

Calculate first. In the print window choose Save as PDF, A4 portrait, scale 100%, and turn off browser headers and footers.
Show calculation basis

Design wind speed: Vz = Vb × k1 × k2 × k3 × k4.

pz = 0.6 × Vz2 (N/m²).
pd = max(Kd × Ka × Kc × pz, 0.70 × pz).
Displayed pressures are divided by 1000 to obtain kPa. NBC 2016, Clause 4.5.2.

Select a city and terrain category to calculate design wind speed.

h/w = full building height ÷ shorter plan dimension.
l/w = longer plan dimension ÷ shorter plan dimension.

City wind speeds: NBC 2016, Part 6, Section 1, Annex C (Clause 4.4.2), transcribed from the supplied table. k₂: Table 5 (Clause 4.4.3.2.2), using full building height h. Between adjacent table heights z₁ and z₂: k₂ = k₂₁ + (k₂₂ − k₂₁) × (h − z₁) / (z₂ − z₁). Supported table range: 10–500 m; values outside this range require a verified code rule. Net façade pressure = (Cpe − Cpi) × pd. Both internal-pressure signs and wind angles 0° / 90° are checked. Local suction uses a separate pd with Kd = 1.00.